![](http://pdfasset.owneriq.net/5/97/5976dcc5-0c64-4047-9a91-30d5e763d322/5976dcc5-0c64-4047-9a91-30d5e763d322-bg37.png)
Troubleshooting Symptom Charts/System - 5
System does not start
up
1 Reset logic board. Refer to Additional Procedures.
2 Replace power supply.
3 Check power cord connection.
4 Replace logic board. Retain customer’s SIMMs.
System will not start
up from keyboard,
but will start up from
rear power switch
1 Verify keyboard as known-good.
2 Replace analog board.
System continually
restarts after
Shutdown from
Special menu
1 Verify keyboard as known-good.
2 Replace analog board.