IT
ECO
Blue
Angel
TCO '03 ECMA
Yes No
Not
rel.
('02)
Desktop
CPUs
Desktop
Display
(6/99)
APES
(Apple's Product Environmental Specifications)
Requirement
met
4
Batteries
4.1
Batteries, defined as hazardous in the EU Directive 91/157/EEC
and amendments 98/101/EC, are not used in the product
X 3.1.4 5.10
4.2
Battery handling information is given in the product documentation X 3.1.4 5.10
4.3
Batteries may not contain mercury (Hg) or cadmium (Cd) X P2.2 3.1.4 A.6.2.1 5.8
4.4
The battery chemical composition:
Logic board/memory/clock battery _____
Power battery _____
X 5.10
5
Energy consumption
5.1
Power supply maximum continuous power rating 150 W A.7.1
at 115V/60Hz, and 175 CD/m
2
Standby: 84.4 W Sleep mode: 0.8 W Off: 0.7 W
at 230V/50Hz, and 175 Cd/m
2
Standby: 79.3 W Sleep mode: 0.9 W Off: 0.7 W
at 100V/50Hz & 60HZ Sleep mode: W X P8.1 4.1.1.6 5.3
5.2
External power supply (AC adaptor) no-load power consumption
at 115v/60Hz _0.4_ watts
at 230v/50Hz _0.5_ watts
5.3
Product meets the requirements of ENERGY STAR® X P8.4 4.1.1.1 5.3
5.4
External power supply/AC Adaptor meets EU CoC (Code of
Conduct) criteria
X
5.5
Product meets US FEMP (Federal Energy Management Program)
criteria
X
5.6
Information about the energy save function is given in the user
manual
X P8.3 5.3
5.7
There shall be a description, from the user's point of view, how the
VDU is brought into energy mode(s) and how this is indicated on
the VDU.
X A.7.1
5.8
The sleep mode is activated automatically X P8.1 4.1.1.2
5.9
The appliance may be separated from the mains for at least 4
weeks without damage to the appliance
X 4.1.1.4
5.10
The computer must be so equipped as to support an operating
system allowing the implementation of power-saving functions. Unit
must offer at least one power-saving rest mode as a special
operating mode. This mode must activate itself automatically after a
factory pre-set activation time
X 4.1.1.2
5.11
First step sleep must be ≤15W, readable screen within 3 sec (5 sec
for AIO). If Sleep ≤5W in second step or in first step then no
wakeup time requirement applies.
X A.7.1
6
Emissions
6.1
Alternating Electric Field: Band I: 5 Hz - 2 kHz, ≤ 10 V/m, measured
30 cm & 50 cm in front of VDU; Band II: 2 - 400 kHz, ≤ 1 V/m,
measured 50 cm around VDU and 30 cm in front of VDU
X A.4.2
6.2
Alternating Magnetic Fields: Band I: 5 Hz - 2 kHz, ≤ 200 nT,
measured 30 cm in front of VDU and at 50 cm around VDU; Band
II: 2 - 400 kHz, ≤ 25 nT measured 50 cm around VDU
X A.4.3
N/A
« Values
N/A
« Values
« Values
« Values
4