ASUS AP1600R 1U Rackmount Server
43
Input Characteristics
A.2 Specifications
Output Characteristics
Over-Voltage Protection (OVP)
Input Voltage Range Min Nom Max
Range 1 90V 100V 140V
Range 2 180V 240V 264V
Input Frequency Range 47 Hz to 63 Hz
Maximum Input ac Current 4.96A max. at 100Vac
2.48A max. at 200Vac
2.75A max. at 230Vac, maximum load
Inrush Current 30A cold start
30A warm start
Efficiency 72% min. at nominal input,
maximum load
Output
Load Range Regulation Ripple
Voltage Min Max Min Max Max
+5V 1.0A 12.0A -4% +5% 50mVp-p
+12V1 1.5A 16.0A -4% +5% 120mVp-p
+12V2 0.5A 16.0A -4% +5% 120mVp-p
-12V 0A 0.5A -5% +9% 120mVp-p
+5VSB 0.1A 2.0A -4% +5% 50mVp-p
+3V3 1.5A 16.0A -3% +5% 50mVp-p
Output Voltage Maximum Voltage
+5V 6.2V
+12V 14.5V
+3.3V 4.5V
+5VSB 6.5V
-12V -14.5V
NOTE
The power supply will shut down and latch off for shorting +5V,
+12V, -12V, or +3.3V. By shorting +5VSB, the power supply can
latch down or automatically recover when the fault condition is
removed. This requires disconnecting then re-connecting the AC
power plug.