Asus E8181 Computer Hardware User Manual


 
ASUS MAXIMUS VI HERO
3-41
Chapter 3
Chassis1/Chassis2/Chassis3 Q-Fan Control [Enabled]
[Disabled] Disables the Chassis Q-Fan control feature.
[Enabled] Enables the Chassis Q-Fan control feature.
Chassis1/Chassis2/Chassis3 Fan Speed Low Limit [600 RPM]
This item appears only when you enable the Chassis Q-Fan Control feature and allows you
to disable or set the chassis fan warning speed.
Conguration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]
The following items appears only when you set the Chassis1/Chassis2/Chassis3 Q-Fan
Control feature to [Enabled].
Chassis1/Chassis2/Chassis3 Fan Profile [Standard]
This item allows you to set the appropriate performance level of the chassis fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust
depending on the chassis temperature.
[Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan
operation.
[Turbo] Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set Chassis1/Chassis2/Chassis3 Fan
Prole to [Manual].
Chassis1/Chassis2/Chassis3 Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the chassis
temperature. The values range from 40ºC to 75ºC.
Chassis1/Chassis2/Chassis3 Fan Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum chassis fan duty cycle.
The values range from 60% to 100%. When the chassis temperature
reaches the upper limit, the chassis fan will operate at the maximum duty
cycle.
Chassis1/Chassis2/Chassis3 Lower Temperature [40]
Displays the lower limit of the chassis temperature.
Chassis1/Chassis2/Chassis3 Fan Min. Duty Cycle(%) [60]
Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle.
The values range from 60% to 100%. When the chassis temperature is
under 40ºC, the chassis fan will operate at the minimum duty cycle.