Asus RS700X7PS4 Network Hardware User Manual


 
6-6 Chapter 6: RAID conguration
3. Select all the drives required for the RAID set, and then press <F10> to
congure array setting.
4. Press <Space> to select the congurable array.
2. The
ARRAY SELECTION MENU
displays the available drives connected to
the SATA ports. Use the up/down arrow keys to select the drives you want to
include in the RAID set, and then press <Space>. When selected, the drive
indicator changes from
READY
to
ONLIN A[X]-[Y]
, where X is the array
number, and Y is the drive number.
The information of the selected hard disk drive displays at the bottom of the
screen.
You need at least two identical hard disk drives when creating a RAID 1 set.
You need at least four identical hard disk drives when creating a RAID 10
set.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
PORT #
DNLIN A00-00
DNLIN A00-01
0
1
Easy Conguration - ARRAY SELECTION MENU
Select Congurable Array(s)
A-0
SPAN-1
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Congure Esc-Quit
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Port # 2 DISK 74.74GB HDS728080PLA380 05.01C05
Easy Conguration - ARRAY SELECTION MENU
PORT #
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
SPACE-Sel,ENTER-EndArray,F10-Congure,F2-Drive Info,F3-Virtual Drives,F4-HSP
2
3