ATEN Technology ACS-1216AL Network Card User Manual


 
Clear Login Information
If you are unable to perform an Administrator login (because the
Username and Password information has become corrupted, or you have
forgotten it, for example), you can clear the login information with the
following procedure:
1. Power off the switch and remove the top cover of the Switch
module case.
2. Short the jumper labeled Default Password at the right front of the
switch’s main board.
3. Power on the switch.
When you power the switch on, the following message appears on
the LCD display:
USERNAME AND PASSWORD INFORMATION HAS BEEN
CLEARED. PLEASE POWER OFF THE SWITCH, REMOVE
THE JUMPER, CLOSE THE CASE, THEN RESTART.
4. After you start back up, the OSD login function acts exactly the
way it did the first time the switch was run (see p. 4-2) and you
can reset passwords for the Administrators and Users.
2003-01-27
ACS-1208AL / ACS-1216AL User Manual
A-4