ATEN Technology CE-300 Switch User Manual


 
1. Introduction
3
System Requirements
Consoles
A VGA, SVGA, or Multisync monitor capable of the highest resolution
that you will be using on any computer in the installation
A PS/2 keyboard
A PS/2 mouse
Stereo microphone and stereo speakers (optional)
Note: If you connect a DDC type monitor to the Local unit, the monitor that
connects to the Remote unit must be able to support the highest video
resolution that the DDC monitor can provide.
Computers
The following equipment must be installed on each computer that is to be
connected to the system:
A VGA, SVGA or Multisync card
A 6-pin mini-DIN mouse port
A 6-pin mini-DIN keyboard port
Cables
Although it is possible to use standard KVM cables to link computers with
PS/2 type keyboard and mouse ports to the CE-300L, for optimum signal
integrity and to simplify the layout, we strongly recommend that you use
the high quality custom KVM cable sets provided with this package.
It is not possible to use standard KVM cables to link computers with AT
type keyboard and mouse ports to the CE-300L. For those computers,
custom KVM cable sets must be used. Contact your dealer for details.
Category 5 cable is the minimum required to connect the local and remote
CE-300 units. Cable of a lesser standard will result in degraded video
signals. For best performance, we strongly recommend Category 5 cable.