Atlantis Land A03-S1501 Power Supply User Manual


 
OnePower Line Interactive UPS (EN)
A03-S1001/A03-S1501 Pag. 20
1.7 Operation Test
1. Connect the UPS to the wall receptacle.
2. Push on the Main Switch to check the Green Line ( ) LED is on.
3. Connect your computer equipment with sockets of the UPS and pull off
the input power cable of the UPS from the wall receptacle to check the
Line ( ) and Inverter( ) LED are flashing every 2 seconds.
Meanwhile, please check if alarm buzzer is beeping.
4. Try the field working condition by running some application programs on
your computer and repeating step.
5. Check if the UPS is initiated properly to support continuous operation.
IMPORTANT NOTICE: Plug the UPS into the wall outlet to charge the UPS for
over 10 hours before using the UPS.
1.8 Front Panel Explanations
On the front panel You can found 4 LED for an easy diagnostic.
LED
Information
LED Line ( )
Green LED remains standstill when Utility is
normal.
Green LED flashes every 2 seconds when the
UPS is in Battery charging mode.
Green LED remains standstill and simultaneously
buzzer alarms continuously when the UPS is in
overload condition.
LED Inverter ( )
Yellow LED flashes every 2 seconds and
simultaneously buzzer alarms continuously when
Utility failure.