4.4 Ethernet port configuration panel
The Ethernet panel is used to configure the communication parameters for the Ethernet link on the
FibreBridge. Some parameters will be “grayed out” if they do not apply to your model of the
FibreBridge or if they have no effect based upon the selected value of a related parameter.
DHCP Server (default = Auto detect)
The FibreBridge Ethernet port is capable of receiving its IP
address from a DHCPP Server. Select “DHCP” to enable
this capability. If autodetect is selected, the FibreBridge will
use the ID address entered using IP Address.
Ethernet Speed (default = Automatic Detection)
Configures the Ethernet port on the FibreBridge to either
10Base-T, 100Base-T or for automatic detection.
IP Address (default = 10.0.0.1)
Sets and displays the current IP address of the FibreBridge.
If DHCP is enabled, this field will display the IP address
assigned by the name server.
IP Gateway (default = 0.0.0.0)
Sets and displays the current IP Gateway of the FibreBridge.
IP Subnet Mask (default = 255.255.255.0)
Sets and displays the current IP Subnet Mask of the
FibreBridge. If DHCP is enabled, this field will display the
Subnet Mask assigned by the name server.
Some options will be “grayed out” on the panel: they are not available because of the type of access mode or FibreBridge model or they have no effect based on other
selections. The chart below shows options available based on model and access method.
Model/Access method
Options
2200/3200
in-band
2200/3200
Ethernet
2200/3200
serial port
4500
in-band
4500
Ethernet
4500
serial port
DHCP Server
●●●●●●
Ethernet Speed
●●●●●●
IP Address
●●●●●●
IP Gateway
●●●●●●
IP Subnet Mask
●●●●●●