ATTO Technology FC-82EN Network Cables User Manual


 
4 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
Celerity FC-81EN Adapter
The ATTO Celerity FC-81EN leverages two next-
generation storage technologies: PCIe 2.0
interconnect and 8-Gigabit Fibre Channel.
With 8-Gb FC speeds of up to 1600 MB/sec. per
channel, the Celerity FC-81EN supports the most
demanding application requirements, including high-
definition video, rich content databases and other
high-bandwidth environments.
ATTO Celerity host adapters are an integrated family
of advanced storage connectivity solutions that are
designed to provide reliable connectivity, intelligence
and scalability.
Technical specifications
One independent Fibre Channel port
8-Gigabit FC data transfer rates
1600 MB/sec. throughput in full-duplex mode
Supports all FC topologies: fabric, arbitrated
loop and point-to-point
ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
Flash ROM for easy field upgrades
FC Class 3 support
Local management and diagnostics
• Buffer credits: 41
ATTO Advanced Data Streaming (ADS™)
Technology
Advanced FC capabilities
Supports SNIA HBA API
Backward compatible with 4-Gb and 2-Gb Fibre
Channel
• Supports target and initiator modes
• Supports Windows
FDMI and WMI
Host bus specifications
x8 mechanical and x8 electrical PCI Express
interconnect
Conforms to PCI Express Base Spec 2.0
Conforms to PCI Express CEM Spec 2.0
PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 6.6 inches
Height: 2.731 inches
Operating temperature: 0-45ºC (32-113ºF)
Storage temperature: -40 to 70ºC (-40 to 158ºF)
Relative humidity: 10 to 90% non-condensing
• 5.3 W (typical)
100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
Easy to install full height connection bracket;
low-profile bracket included in finished goods
packaging
External LEDs for on-line and speed status for
each channel
One pluggable 8-Gb optical LC SFP+ module
included
Software specifications
Windows 7®, XP®, Vista®
Windows Server® 2003, 2008
Mac® OS X 10.4.x and up
RedHat Enterprise Linux®
4.x (2.6.x kernels)
RedHat Enterprise Linux®
5.x (2.6.x kernels)
RedHat Enterprise Linux®
6.x (2.6.x kernels)
• SUSE Linux Enterprise® 9.x (2.6.x kernels)
SUSE Linux Enterprise® 10.x (2.6.x kernels)
Fedora Core® Linux 7.x (2.6.x kernels)
Fedora Core® Linux 8.x (2.6.x kernels)
VMware ESX Server® 3.5 - 4.1