5-14 Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1
Chapter 5
Figure 5-3. Detailed Physical Port Configuration Dialog Box for
Port on Gigabit Ethernet Module
6. Enter a port name in the Name field, if desired, or use the
default name supplied
7. Select one of the following from the Category field pull-
down menu:
— User Port if this is an end-station port
— Service Port if this is a trunk port.
8. Select one of the following options from the Flow Control
Mode field pull-down menu:
Enable – Set flow control to prevent buffer overflows.
Disable – When flow control is causing congestion in other
areas of the network.
Enable (Send Only) – Set flow control to prevent buffer
overflows on sent traffic.
Enable (Respond Only) – Set flow control to prevent
buffer overflows on respond traffic.
9. Select Enable from the Auto Negotiation Mode field pull
down menu
10. Select Enable from the Full Duplex Flow Control
Advertisement field pull down menu
11. Select Enable from the Pace Priority Mode field pull
down menu to recognize and use 3Com’s PACE priority
mechanism.