Avaya P580 Switch User Manual


 
Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1 5-39
Configuring Port Parameters
2. Click Configuration.
The Module Information Web page opens.
3. In the Ports column, click the number for the module that
you want to view GBIC types for.
The Physical Port Configuration Web page opens (Figure 5-2
for Gigabit modules and Figure 5-4 for 10/100 modules).
CLI Command To use the CLI to view the type of GBICs that are connected to the
modules in your switch:
1. Enter either the User, Privileged, or Global Configuration
mode.
* Note: For information on how to enter these modes,
see “Accessing/Exiting the Command Modes” in
Chapter 1, “Overview,” of Command Reference
Guide for the Avaya P550R, P580, P880, and P882
Multiservice Switches, Version 5.3.
2. Enter the following command:
show port physical [{<mod-num> | <mod-swport-range>}
[...,{<mod-num> | <mod-swport-range>}]]
The type of GBIC that is connected to each port is displayed in
the Connector field.
SNMP MIB
Object
To use SNMP to view the type of GBICs that are connected to the
modules, use the MIB objects that are listed in Table 2. These MIB
objects are located in ProminetMib.txt, version 5.2.
Network Error Detection and Recovery
Overview
The Network Error Detection and Recovery (NEDR) feature
monitors Ethernet CRC errors on Ethernet data ports and compares
Table 2. MIB, MIB Object, and OID for GBIC Identification
MIB MIB Object OID
ProminetMib.txt,
version 5.2
promPortConnector 1.3.6.1.4.1.2167.3.6.1.1.1.7