2.7 Physical Interconnect Specification
2.7.1 Mechanical Characteristics
Item
Test
Condition
Requirements
Vibration
ANSI/EIA-364-28, Condition III Method
5A, 15 minute/axis
No discontinuity at 1us or longer (each
contact) when continuity is tested
per ANSI/EIA-364-46
Mechanical Shock
ANSI/EIA-364-27 Condition A
(specified pulse)
No discontinuity at 1us or longer (each
contact) when continuity is tested
per ANSI/EIA-364-46
Durability
ANSI/EIA-364-09
Automatic
cycling
to
100
cycles
Rate: 10050 cycles per hour
Low Level contact resistance per
ANSI/EIA-364-23
10 m maximum change from
initial per contact pair
All sample to be mated
Mating &
Un-mating
Forces
ANSI/EIA-364-13
Insert and extract at a speed of
25mm/minute
Un-mating force:
1 kg force minimum,
4 kg force maximum
Mating force:
4.5 kg force maximum
Cable Pullout Force
Test for cable strain relief &
termination integrity. Cable
subjected to 11.3 kg(25.0 lbs) static
load for one minute while
monitoring continuity. Isolate
plug & receptacle interface
from load
No discontinuities greater than 1 us