5.1.4.4 HOST ADDRESS
By responding to the Enter Selection: message at the end of the Reporting Setup
Menu on page 23 with "4" (Host Address), you may program the address of the
designated host module. The designated host module is where event samples are
sent when using Immediate or Schedule Reporting Method. The PDI will respond
with the Host Address menu as follows:
HOST ADDRESS
Host Address.......................1:1,1
Enter Unit Number (1-32) <cr>, or X to EXIT:
Enter Module Number (1-16) <cr>, or X to EXIT:
Enter Port Number (1-4) <cr>, or X to EXIT:
Enter the appropriate Host Address. This consists of the Unit Number (1 to 32),
Module Number (1 to 16), and Port Number (1 to 4) where the designated host
module is located. Each entry should be followed by <ENTER>. If there is a
single M Series unit in service, the Host Address would typically be Unit 1, Module
1, Port 1.
NOTE: The Host Address must be supplied to direct self-reporting event samples
to the desired destination. If the Host Address is incorrect, self-reporting event
samples will be misdirected or lost.
5.1.4.5 TIME TAG
By responding to the Enter Selection: message at the end of the Reporting Setup
Menu on page 23 with "6" (Time Tag), you may program the PDI to append a
time tag to the end of event samples automatically. The PDI will respond with the
Enable/Disable Time Tagging menu as follows:
ENABLE / DISABLE TIME TAGGING
Time Tagging.......................DISABLED
Enable.............................1
Disable............................2
Exit...............................X
Enter Selection: