B&B Electronics RT12-2222-ZP-12 Mouse User Manual


 
Manual Documentation Number: RT-12 series-4006m 11
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Power: 10.5~28 Vdc
Most DC power supplies rated from 10.5 to 28 Vdc @ 1000mA, will work with the
RT12-4444-9T-W20. Do not use a power supply rated less than 1000mA. Doing so
may cause the RT12-4444-9T-W20 to continuously reset. Make sure that the power
supply voltage is maintained between the programmable HIGH and LOW supply
voltage limits or an alarm may occur. If a rechargeable battery is used or if you are
supplying voltage to a sensor using the same power used to power the RT12-4444-9T-
W20, then the input voltage will need to be adjusted to the proper voltage to maintain
respective equipment. Never exceed 28 Vdc. Damage by overheating to the controller
will occur causing the system to malfunction.
Data Activity LED Indicators
The RT12-4444-9T-W20 RTU is equipment with four LED indicators. The
RED/GREEN pair labeled “SERIAL”, indicate data transmit and data received. The
RED LED will blink when data is being transmitted The GREEN LED will blink any
time data is received, this is true for the MASTER and SLAVE.
Link/Sanity LED Indicators
The yellow LED indicator labeled “Status” indicates proper system operation. The
second yellow LED indicator, labeled “Error”, will flash any time an alarm is
programmed and the respective alarm is active.
Serial RS-232 Interface
Used to configure the RTU. See “Software Setup”.
12 Manual Documentation Number: RT-12 series-4006m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
The RT12-4444-9T-W20 has two rows of 10, screw type, connections. Using a
common type screwdriver, loosen the respective terminal screw, insert the respective
wire and tighten.
The front panel is stenciled with each Connection number. Listed below are the
respective Connection numbers and Connection description.
Connection Screw Terminals Description
Pin 1: “AO 1” (+) Analog Output - 1, 0-5 Vdc
Pin 2: “AO 2” (+) Analog Output - 2, 0-5 Vdc
Pin 3: “AO 3” (+) Analog Output - 3, 0-5 Vdc
Pin 4: “AO 4” (+) Analog Output - 4, 0-5 Vdc
Pin 5: “DO 1” (+) Digital Output - 1, Open Drain, Active Low, Output
Pin 6: “DO 2” (+) Digital Output - 2, Open Drain, Active Low, Output
Pin 7: “DO 3” (+) Digital Output - 3, Open Drain, Active Low, Output
Pin 8: “DO 4” (+) Digital Output - 4, Open Drain, Active Low, Output
Pin 9: “GND” (-) Main Supply GROUND
Pin 10: “VIN+” (+) Main Supply 10.5 to 28.0, Must be > 13.0 to Charge
External Battery. Do Not Exceed 28 Vdc
Pin 11: “AI 1” (+) Analog Input - 1, 0-5 Vdc
Pin 12: “AI 2” (+) Analog Input - 2, 0-5 Vdc
Pin 13: “AI 3” (+) Analog Input - 3, 0-5 Vdc
Pin 14: “AI 4” (+) Analog Input - 4, 0-5 Vdc
Pin 15: “DI 1” (+) Digital Input - 1, Active Low, 0~12 Vdc
Pin 15: “DI 2” (+) Digital Input - 2, Active Low, 0~12 Vdc
Pin 15: “DI 3” (+) Digital Input - 3, Active Low, 0~12 Vdc
Pin 15: “DI 4” (+) Digital Input - 4, Active Low, 0~12 Vdc
Pin 19: “Batt” (+) Battery Charge During Normal Main Power Input.
Battery Backup during Main Power Fails.
Pin 20: “GND” (-) Battery Ground