Connecting a USB Device
1. Install any software required to operate the USB device(s). Refer
to the documentation for the device(s), as required.
2. Connect the USB device to the Device port on the Remote Unit.
3. Check that the Device LED on the Remote Unit is on.
8
Manual Documentation Number: UEC100M/4-2305
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Troubleshooting
The following table provides troubleshooting help. The topics are arranged
in the order in which they should be executed in most situations. If you are
unable to resolve the problem after following these instructions, please
contact technical support for further assistance (see page 12).
Symptoms/Cause
Remedy
All LEDs on Local Unit and
Remote Unit are off.
Cause:
The Ulinx Extender is not
receiving power from the
adapter
1. Ensure that the power adapter is connected to
the Local Unit or Remote Unit
2. Check that the adapter is connected to a live
source of electrical power
Power LED on one unit is
on, power LED on other unit
is off.
Cause:
There is no connection
between the Local Unit and
Remote Unit.
1. Ensure that a Category 5 UTP cable with
straight-through conductors is connected
between the Local Unit and Remote Unit.
2. Connect a short Category 5 patch cord
between the Local Unit and Remote Unit.
Recheck the operation of the system.
Link LEDs on Local Unit
and Remote Unit are off.
Cause:
There is no connection
between the Local Unit and
Remote Unit.
3. Ensure that a Category 5 UTP cable with
straight-through conductors is connected
between the Local Unit and Remote Unit.
4. Connect a short Category 5 patch cord
between the Local Unit and Remote Unit.
Recheck the operation of the system.
USB Hub Power
Exceeded
message is
displayed by the computer.
Cause:
The USB device connected
to the Remote Unit is a
high-power device and the
power adapter is connected
to the Local Unit
5. Move the power adapter from the Local Unit to
the Remote Unit.