BEA w/ LO-21 Switch User Manual


 
SIZE:
DRAWN BY:
TITLE: BODYGUARD DUAL EGRESS
A
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
KJG KJG
80.0075.02
SCALE: DATE:
NONE 07 AUG 05
PART NO:
SHEET
1 OF 1
RED
GREEN
OFF
ON
LO21 DEFAULT DIP SWITCHES
RED
BLACK
24 V
TRANSFORMER
WHITE
RED/ WHITE
DOOR
CONTROL
SAFETY
ACTIVATION
COM
MOTOR
BODYGUARD BODYGUARD
NOTES: 1) OPEN DOOR PATTERNS CANNOT OVERLAP
2) STANDARD 80 TO 84 INCH OPENINGS SPACE BODYGUARDS 15 INCHES FROM CENTER DOOR OPENING TO
BODYGUARD CENTER. RH TRAFFIC SET OPEN DOOR PATTERN TO #3 FOR SMALLER DOOR OPENINGS
SPACE BODYGUARDS SAME AS ABOVE USING PATTERN #9. THESE ARE SUGGESTED SETTINGS; ALWAYS
WALK TEST SAFETY PATTERNS AND CHANGE IF NEEDED.
BODYGUARD
BODYGUARD
30" MIN
+
-
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM