Belkin F5C520 Surge Protector User Manual


 
Setting up your ReSource
®
1. Plug ReSource
®
into a 3-prong grounded outlet. If the “Wiring OK” light does not light up please refer to the “Wiring OK” section below.
2. Plug your PC power supply and monitor power supply to the outlets marked “Instant Back Up Power Supplied”. Plug in any other devices that may
require back up power in case of a utility power outage (e.g., external storage drive, or tape backup, external modem.)
3. Printers and other peripherals that are not crucial to battery back-up, but still need maximum surge protection should be plugged into the four
remaining outlets that are opposite the Instant Back Up Power Supplied outlets. These outlets have full surge protection but are not powered by the
battery during utility power outages.
4. The ReSource
®
comes with Solid State Phone/Fax/Modem surge protection. Instead of running a connection directly from your Phone/Fax/Modem
to the wall jack, you must pass the connection through the protected jacks on your ReSource
®
. Connect your phone/fax/modem line from your wall
outlet to the “Input” jack on ReSource
®
. Connect the 6-foot phone cord provided with ReSource
®
into the “Output” jack, and connect the other end of
the phone cord to the Phone/Fax/Modem jack of the device you want to protect. If you fail to connect the Phone/Fax/Modem protection your
connected equipment will not be covered by the Connected Equipment Warranty. Most modem damage can be prevented if you take the time to
connect the Phone/Fax/Modem protection.
5. The ReSource
®
also comes with 10Base-T Network protection. Instead of running a connection directly from your network wall jack to your PC, you
must pass the connection through the protected jacks on your ReSource
®
. Connect your RJ45 Network line (Category 5 cable) from your wall outlet
to the "Input" jack on ReSource
®
. Connect the 5 foot long CAT 5 patch cable provided into the “Output” jack on ReSource
®
, and connect the other
end to the Network connection on the back of your PC. If you fail to connect the Network protection when using ReSource
®
with a Network
your connected equipment will not be covered by the Connected Equipment Warranty.
6*. Connect the RS232 cable to the ReSource
®
and your PC to utilize the shutdown software. (See: Installing Shutdown Software)
7. Switch on your ReSource
®
- the “Powered” light will come on. It will stay on as long as the switch remains on and power is supplied to the unit.
* For Models F5C510 and F5C520
Internet Ready
Solid state
phone/fax/modem
protection (6 ft. phone
cord included)
Eight 3-line A/C
surge protected
outlets
BlockSpace
provides extra
space for large A/C
adapters
10Base-T network protection with RJ45 jacks.
(5 ft. CAT 5 cable included)
Four battery back-up outlets
provide running time
SURGE PROTECTED indicates the surge protection
is functioning properly
15 Amp re-settable circuit
breaker (Recessed for safety)
WIRING OK lets you know the outlet ReSource
®
is plugged into is grounded correctly
CHECK BATTERY
warns if the battery
needs replacement
Recessed MAIN
power switch helps
prevent accidental
shut-off
Heavy-duty, impact
resistant ABS case
Heavy duty 6
foot cord
IMPORTANT SAFETY INSTRUCTIONS
• This manual contains important instructions for Model F5C500, F5C510 and F5C520 that should be followed during installation and maintenance of the UPS
and batteries. Please save this instruction manual.
• The unit is intended for installation in a temperature-controlled indoor area free of conductive contaminants.
• To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the
National Electrical Code, ANSI/NFPA 70.
• Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized
personnel away from batteries.
Communication Port
RS232 Serial Port
(For models F5C510 (450VA)
and F5C520 (600VA) only)