MODEL F5C500 (325VA) MODEL F5C510 (450VA) MODEL F5C520 (600VA)
Max. Load for Full Time Surge Protection Outlets 125 V, 1800W, 15A (Total) 125 V, 1800W, 15A (Total) 125 V, 1800W, 15A (Total)
Max. Load utility Power Supplied outlets (4 outlets) 125 V, 1500W, 12A 125 V, 1400W, 11 A 125 V, 1250W, 10A
Max. Load for Battery Power Supplied outlets (4 outlets) 325VA,180W, 2.5 A 450VA,250W, 3.6 A 600VA, 330W, 4.8 A
Brownout Voltage Transfer to Battery 95 Vac, typical 95 Vac, typical 95 Vac, typical
Overvoltage Transfer to Battery 135 Vac, typical 135 Vac, typical 135 Vac, typical
On-Battery Output Voltage 120 Vac +
5% 120 Vac + 5% 120 Vac + 5%
Transfer Time 3 ms typical, 6 ms maximum 3 ms typical, 6 ms maximum 3 ms typical, 6 ms maximum
Surge Energy Rating H-N, H-G, N-G 1260 Joules 1260 Joules 1260 Joules
EMI/RFI Noise Filter Frequency Range: 150kHz - 100MHz Frequency Range: 150kHz - 100MHz Frequency Range: 150kHz - 100MHz
Attenuation: up to 58 db Attenuation: up to 58 db Attenuation: up to 58 db
Operating Temperature +32˚ to +95˚ F (0 to 35 C) +32˚ to +95˚ F (0 to 35 C) +32˚ to +95˚ F (0 to 35 C)
Operating Relative Humidity 0 to 95% non-condensing 0 to 95% non-condensing 0 to 95% non-condensing
Typical Battery Recharge Time 12 hours from total discharge 12 hours from total discharge 12 hours from total discharge
Typical Battery Life 3-6 years 3-6 years 3-6 years
Size (L x W x H) 16 1/8” x 6” x 3” 16 1/8” x 6” x 3” 16 1/8” x 6” x 3”
Net Weight 8.15 Lbs. 8.75 Lbs. 8.8 Lbs.
UL Listings 1449, 1778 1449, 1778 1449, 1778
ReSource
®
Specifications
Pentium 200MHz
with 17” Monitor
Pentium 166MHz
with 15” Monitor
Pentium 133MHz
with 15” Monitor
Power Mac
Power PC with
17” Monitor
Pentium 90MHz
with 15” Monitor
ReSource
®
325VA
Battery Runtimes with
Common Systems
10-12
Minutes
10-12
Minutes
Pentium II 400MHz
with 17” Monitor
Pentium II 350MHz
with 15” Monitor
Pentium II
333MHz/G3
with 15” Monitor
Power Mac
Power PC with
17” Monitor
Pentium II 233MHz
with 15” Monitor
ReSource
®
450VA
Battery Runtimes with
Common Systems
Pentium II 400MHz
with 17” Monitor
Pentium II 350MHz
with 15” Monitor
Pentium II
333MHz/G3
with 15” Monitor
Power Mac
Power PC with
17” Monitor
Pentium II 233MHz
with 15” Monitor
ReSource
®
600VA
Battery Runtimes with
Common Systems
20-25
Minutes
16-18
Minutes
8-10
Minutes
10-12
Minutes
12-15
Minutes
Important Safety Instructions
This manual contains important instructions for Model F5C500, F5C510 and F5C520 that should be followed during
installation and maintenance of the UPS and the batteries.
The unit is intended for installation in a temperature-controlled indoor area, free of conductive contaminants.
To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent
protection in accordance with the National Electrical Code, ANSI/NFPA 70.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required
precautions. Keep unauthorized personnel away from batteries.
18-20
Minutes
18-20
Minutes
12-14
Minutes
5-6
Minutes
8-10
Minutes
13-15
Minutes
14-16
Minutes
20-25
Minutes