Belkin F6H350ukUNV Power Supply User Manual


 
Using the Serial or USB cable (included with purchase),
connect the desired cable to your UPS then connect the
other end to the Serial or USB port on your computer.
Caution: Use only the Belkin-supplied
UPS monitoring cables.
USB: HID Windows Setup Procedure
*For installation on other operating systems,
please consult the software’s manual
Hardware Installation
1. Connect the Serial/USB cable to the battery
backup’s communication port.
2. Connect the Serial/USB cable to the
PC’s communication port.
3. Make sure the communication port selector on the back
of the battery backup is either on “USB” or RS-232
(Serial). Only one communication port can be used.
Do not connect both USB and Serial at the same time.
Software Installation
1. Insert the Belkin Power Management Software CD to the
CD-ROM. The software will display the installation menu,
or your can select ‘run’ from windows start menu and
execute ‘setup.exe’. Belkin Power Management Software
fi les will be copied into the directory you appointed. When
the software has been launched, the operating system will
select the local language in the software for displaying. If
there is no preferred language, the Software will default to
use English interface.
(Default:C:\Program Files\Belkin Power
Management Software\)
2. After installation. For Windows 95/98, check if
there is a ‘Rupsmon Daemon’ icon in task bar.
For Windows NT, go to ‘control panel->service’
and check if ‘Rupsmon’ service has started
3. Click ‘Belkin Power Management
Software’ for parameter settings.
4. Click ‘Select UPS’ to monitor local or remote UPS.
5. Click ‘Settings’ to set ‘Communication Type’ and ‘Select
Comm Port’. If you see ‘Communication with UPS’ on
the main screen, this means you have connected with UPS.
Uninstall Belkin Power Management Software
To uninstall the shutdown software and remove it
from the system, please go to Windows start menu \
“Belkin Power Management Software Uninstall.”
TECHNICAL SPECIFICATIONS
All specifi cations are subject to change without prior notice.
STORAGE
Storage Conditions
Store the UPS covered and upright in a cool, dry location with its
battery fully charged. Before storing, charge the UPS for at least
four hours. Disconnect any cables connected to the computer
interface port to avoid unnecessary drainage of the battery.
Extended Storage
During extended storage in environments where the
ambient temperature is +5 o F to +86 o F, charge the UPS
battery every six months. During extended storage in
environments where the ambient temperature is +86 o F to
+113 o F, charge the UPS battery every three months.
Note:
Away from sunlight Away from heat Away from water
Belkin Corporation User License Agreement
Belkin Corporation (“Belkin”) thanks you for choosing
one of our products. This User License Agreement
(“Agreement”) contains the terms and conditions under
which limited use of the product is licensed to you.
PLEASE READ THIS NOTICE CAREFULLY. DO NOT
USE THE SOFTWARE OR PRODUCT UNTIL YOU HAVE
READ AND AGREED TO THIS AGREEMENT. IF YOU USE
THE SOFTWARE AND PRODUCT, YOU ARE AGREEING
TO THE TERMS AND CONDITIONS SET OUT IN
THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE
TERMS AND CONDITIONS, YOU MUST RETURN THE
UNOPENED PRODUCT WITH THE DISKS INSIDE TO
THE PARTY FROM WHOM YOU RECEIVED IT.
SCOPE OF USE: In this Agreement, software means all
machine-readable software programs and associated fi les
in this package. All modifi ed versions of and upgrades
or improvements to such programs and all copies of
such programs and fi les. You, a single user opening
this envelope (You or Your), may use the software on a
single central processing unit. You may not rent it, loan
it out, or lease it, nor use it on a multi-user system.
LICENSE: You have the non-exclusive right to use the
software. You are not permitted to copy, modify or
transfer the software or documentation. You may not
compile, disassemble or otherwise reverse engineer,
breakdown, analyze or modify the software.
USE AND RESTRICTIONS: You are permitted to make
backup copies of all the software disks for archival purposes
only. You must reproduce the proprietary notice set forth
on the disks and affi x them to all backup copies. You
are not permitted to use these programs in connection
with a computer service, or to use the backup copies
other than as a replacement for the original copy.
TERM: This license is effective upon acceptance by opening
this envelope or in any other way using the enclosed software,
which will constitute your acceptance of, and agreement
to, this Agreement, and is effective until terminated. The
limited license in this Agreement will be automatically
terminated if you fail to comply with any of the Terms and
conditions in this Agreement. You agree that upon such
termination you will immediately destroy all programs and
documentation, including all copies made or obtained by you.
SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY
RELATED INFORMATION, GOODS OR SERVICES ARE
PROVIDED WITH NO WARRANTY OR REPRESENTATION
OF ANY KIND WHATSOEVER. BELKIN HEREBY
DISCLAIMS ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO
THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
The entire risk of the use, results and performance of
the software, program and documentation is borne by
you. Should any or all of the product, software, program,
documentation, or related information, goods or services
be defective, misused, unsuitable or cause or give rise
to any harm or liability whatsoever, you, not Belkin or its
associates, dealers or agents, assume the entire liability,
cost of repair, correction or any payment or other remedy
whatsoever. Furthermore, no warranty or guarantee is
made regarding the use or results of the product, software,
program, documentation, or any related information, goods
or services in terms of correctness, accuracy, reliability,
timeliness or otherwise. You use and rely on the program
at your own risk. The following is the only and exclusive
warranty and remedy of any kind: Belkin does warrant that
the program disks are free from physical defects in materials
and workmanship under normal use for a period of one (1)
year from the date of purchase, as evidenced by a copy of
the sales receipt. Return the defective disk or documentation
with your receipt directly to Belkin for a replacement.
DISCLAIMER: Belkin or its associates will in no event be
liable (i) in any amount for lost profi ts or special, incidental,
punitive or consequential damages, or (ii) for any claim or
damage of any nature, or under any theory, whatsoever, in
any amount in excess of the purchase price you paid for
the product. The warranties and remedies here set forth are
exclusive, and in lieu of all others oral or written, express
or implied. Some jurisdictions do not allow exclusion or
limitation of implied warranties or of liability for incidental
damages, so the foregoing limitations or exclusion may
not apply to you. This warranty gives you specifi c legal
rights, which vary from jurisdiction to jurisdiction.
HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT
AS EXPRESSLY PROVIDED UNDER THE TERMS
AND CONDITIONS OF THIS AGREEMENT, TO
THE MAXIMUM EXTENT ALLOWED BY LAW.
The license is governed by the laws prevailing in the State of
New York, without regard to its confl icts of laws principles.
ACKNOWLEDGMENT:
By opening the package on which this Agreement is
printed, or through which it is visible, you acknowledge
that you have read this Agreement, understand it,
and agree that this Agreement is the complete and
exclusive statement of agreement between yourself
and Belkin and supersedes any prior agreements,
oral or written, and any other communications
relating to the subject matter of this Agreement.
SEVERABILITY:
Any term or provision of this Agreement or any application
thereof, which may be prohibited or unenforceable by law in
a particular jurisdiction, shall be interpreted and enforced to
the maximum extent allowed in such jurisdiction (which the
parties acknowledge could mean severing the provision from
this Agreement or, if allowed, enforcing it in a narrower form),
without affecting the remainder of this Agreement, or any
other application of such term or provision in such jurisdiction,
or application of such term or provision in any jurisdiction.
SAFETY INFORMATION
CAUTION!
• Internal battery voltage is 12V DC.
The unit is intended for installation in a controlled
environment (temperature controlled, indoor
area free of conductive contaminants).
All batteries used are sealed lead batteries.
Batteries must be recycled.
Please visit belkin.com for battery replacement information.
Recycling Information
Your UPS contains a non-spillable, sealed lead battery. On
the battery, you will fi nd the battery name. Please take the
time to properly recycle the battery in a proper manor.
CONTACT BELKIN
To contact Belkin for any reason, please fi nd our
international offi ce contact information below.
Belkin Corporation
501 West Walnut Street
Compton, CA, 90220-5221, USA
+1 310 898 1100
+1 310 898 1111 fax
Belkin Ltd.
Express Business Park
Shipton Way, Rushden, NN10 6GL, United Kingdom
+44 (0) 1933 35 2000
+44 (0) 1933 31 2000 fax
Belkin B.V.
Boeing Avenue 333
1119 PH Schiphol-Rijk, The Netherlands
+31 (0) 20 654 7300
+31 (0) 20 654 7349 fax
Belkin GmbH
Hanebergstrasse 2
80637 Munich, Germany
+49 (0) 89 143405 0
+49 (0) 89 143405 100 fax
Belkin SAS
5 Rue du Petit Robinson, 3ème étage
78350 Jouy en Josas, France
+33 (0) 1 34 58 14 00
+33 (0) 1 39 46 62 89 fax
Belkin Nordic
Knarrarnäsgatan 7
164 40 Kista, Sweden
+46 (0) 8 5229 1870
+46 (0) 8 5229 1874 fax
Belkin Ltd.
7 Bowen Cresent, West Gosford
NSW 2250, Australia
+61 (0) 2 4372 8600
+61 (0) 2 4372 8603 fax
Belkin Tech Support
Europe: 00 800 223 55 460
US: 877 736 5771
www.belkin.com
TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
UPS not on,
LED not lit
On/Off/Test button
not pushed or pushed
less than 3 seconds
Press the On/Off
/Test button for more
than 3 seconds
Battery voltage
is too low
Recharge the UPS
at least 12 hours
UPS fault
Contact Belkin
Technical Support
UPS always on
battery mode
Power cord loose
Re-plug the
power cord
AC breaker is burned
out or tripped
Replace or reset
the breaker
AC utility voltage
is too high or too
low, or blackout
Normal condition
Backup time
too short
Battery not fully
charged
Recharge the UPS
at least 12 hours
UPS is overloaded
Check wattage of
connected equipment
and remove some
unnecessary loads
Charger fault or
other reason
Replace battery.
Contact Belkin
Technical Support
The UPS
continuously
beeps
Overload
Remove the
non-critical loads
MODEL
F6H350ukUNV F6H500ukUNV F6H650ukUNV
INPUT
Capacity 350VA / 210W 500VA / 300W 650VA / 390W
Voltage
Range
220-250 VCA/ 10 A
Frequency 50 Hz (±3 Hz)
OUTPUT
Voltage 230 VCA +/- 6 %
Frequency
(on battery)
50 Hz (±1 Hz)
BATTERY
Backup
time
5-10 min. 7-12 min. 10-15 min.
Under/Over
Voltage
Transfer to
Battery
165~276 VCA +/- 6 %
Typical
Recharge
Time
12 hr. (charge prior to use)
SURGE
PROTECTION
Max. Spike
Amps /
Joules
Max. Spike Amperage: 45,000 Amps / 1620 Joules
Conformance
Safety Complies to British Safety Standards
PHYSICAL
Dimensions
(L X W X H)
363x141x90 mm 363x141x107 mm
Net Weight 4.89 kg 5.94 kg 6.16 kg
P74778uk_F6H350_500_650
P74778uk_F6H350_500_650.indd 2 7/7/05 3:44:38 pm