BenQ MP525 ST Projector User Manual


 
Maintenance 57
Indicators
Light Status & Description
Power events
Orange Off Off
Stand-by mode.
Green
Flashing
Off Off
Powering up.
Green Off Off
Normal operation.
Orange
Flashing
Off Off
The projector needs 90 seconds to cool down as it
was abnormally shut down without the normal
cooling down process.
The projector needs to cool for 90 seconds after the
power is turned off.
The projector has shut down automatically. If you try
to re-start the projector, it will shut down again.
Please contact your dealer for assistance.
Lamp events
Orange
Flashing
Off Red
The projector has shut down automatically. If you try to
re-start the projector, it will shut down again. Please
contact your dealer for assistance.
Off Off Red
1. The projector needs 90 seconds to cool down. Or
2. Please contact your dealer for assistance.
Thermal events
Off Red Off
The projector has shut down automatically. If you try to
re-start the projector, it will shut down again. Please
contact your dealer for assistance.
Off Red Red
Off Red Green
Off Red Orange
Red Red Red
Red Red Green
Red Red Orange
Green Red Red
Green Red Green
Green Red Orange
Orange Red Red
Orange Red Green
Orange Red Orange
Off Green Red
Off Green Green