BenQ MP525P Projector User Manual


 
Maintenance 59
14. Restart the projector.
Do not turn the power on with the lamp cover removed.
Resetting the lamp timer
15. After the start-up logo, press Menu/Exit and then press / to highlight the
SYSTEM SETUP: Advanced menu.
16. Press to highlight Lamp Settings and press Mode/Enter. The Lamp Settings page
is displayed.
17. Press to highlight Reset Lamp Timer and
press Mode/Enter. A warning message is
displayed asking if you want to reset the lamp
timer. Highlight Reset and press Mode/Enter.
The lamp time will be reset to "0".
Do not reset if the lamp is not new or replaced as this
could cause damage.
10. Tighten the screw that secures the lamp.
Loose screw may cause a bad connection, which
could result in malfunction.
Do not over tighten the screw.
11. Ensure the handle is fully laid flat and locked in
place.
12. Replace the lamp cover on the projector.
13. Tighten the screws that secure the lamp cover.
Loose screw may cause a bad connection, which
could result in malfunction.
Do not over tighten the screw.
Reset Lamp Timer?
Reset
Cancel
Notice