BIXOLON SRP-352 Printer User Manual


 
Rev. 1.00
- 13 -
SRP-350/352plusIIA&C
1-5 Setting the Memory Switches
This printer has “Memory Switch” set which is software switches. Memory Switch set has
“MSW1”, “MSW2”, “MSW8”, “MSW9” “Customize value”, “Serial communication condition”.
“Memory Switch setting utility” can change the Memory Switch set to ON or OFF as shown
in the table below. (default : all OFF)
NOTE
The Memory Switch is available to be changed by three methods.
- Memory Switch setting utility.
- Control from BXL/POS command.
Settings of the Memory Switch are stored in the NV memory : therefore, even if the printer
is turned off, the settings are maintained.
MSW1
Switch Function ON OFF
1
2
Select Print Speed Refer to following Table
3~8 Reserved -- Fixed to OFF
180dpi
MSW 1-2 MSW 1-1 Print Density Remark
OFF OFF Print Density 3 250mm/s
OFF ON Print Density 2 230mm/s
ON OFF Print Density 1 200mm/s
203dpi
MSW 1-2 MSW 1-1 Print Density Remark
OFF OFF Print Density 3 230mm/s
OFF ON Print Density 2 200mm/s
ON OFF Print Density 1 180mm/s
MSW2
Switch Function ON OFF
1
Specification for
Destination
Double byte Country Single byte Country
2 Reserved -- Fixed to OFF
3
4
5
6
7
8
Code Page Selection Refer to following Table