Black Box 26/48- Port Gigabit Managed Switch CLI Guide Switch User Manual


 
&%$
724-746-5500 l www.blackbox.com
&))

         


#*$+#


  !"&!'$(
"
"

Switch(stp)# p-autoEdge aggregations enable
Switch(stp)# show pconf
Port Mode AdminEdge AutoEdge restrRole restrTcn bpduGuard Point2point
---- -------- ------------------ ------------------ ---------------------
Aggr Disabled Disabled Enabled Disabled Disabled Disabled Enabled
Port Mode AdminEdge AutoEdge restrRole restrTcn bpduGuard Point2point
---- -------- ------------------ ------------------ ---------------------
1 Disabled Disabled Enabled Disabled Disabled Disabled Auto
2 Disabled Disabled Enabled Disabled Disabled Disabled Auto
3 Disabled Disabled Enabled Disabled Disabled Disabled Auto
Switch(stp)# p-autoEdge 1 disable
Switch(stp)# show pconf
Port Mode AdminEdge AutoEdge restrRole restrTcn bpduGuard Point2point
---- -------- ------------------ ------------------ ---------------------
Aggr Disabled Disabled Enabled Disabled Disabled Disabled Enabled
Port Mode AdminEdge AutoEdge restrRole restrTcn bpduGuard Point2point
---- -------- ------------------ ------------------ ---------------------
1 Disabled Disabled Disabled Disabled Disabled Disabled Auto
2 Disabled Disabled Enabled Disabled Disabled Disabled Auto
3 Disabled Disabled Enabled Disabled Disabled Disabled Auto
Switch(stp)# msti-vlan add 1 4094
Switch(stp)# show msti-vlan
MSTI VLANs mapped to MSTI
---- --------------------
MSTI1 4094
MSTI2 No VLANs mapped
MSTI3 No VLANs mapped
MSTI4 No VLANs mapped
MSTI5 No VLANs mapped
MSTI6 No VLANs mapped
MSTI7 No VLANs mapped
   