Black Box PC471C Network Card User Manual


 
35
CHAPTER 5: Utility Software
“1” will result in the diagnostics being run once.
“2” will result in the tests being run a user-specified number of times.
(This mode is useful when searching for an intermittent problem.)
“3” exits the diagnostic program and returns control to MS-DOS
®
.
If option “1” on the main menu is selected, the diagnostic tests are run once. If any
test fails, an error code and error message are displayed. Otherwise, if the main
tests run successfully, the user is asked whether the online tests should be run.
If you enter “NO,” several tests run which check the Adapter in an offline mode.
If you enter “YES,” the Adapter must be connected to the host. A list of active
addresses is then displayed, and you are prompted for the station addresses to use.
Either one primary address or a primary and a secondary address may be entered.
NOTE
Enter an “N” for the secondary address if only one address is to be
used. If only one address is entered, this address is used twice during
the tests.
If all tests run with no errors, the message
Test Complete
is displayed, and you are prompted to hit any key, which causes the main menu to
be redisplayed.
If option “2” on the main menu is selected, the diagnostic tests are set to loop. You
are then asked how many times to loop. This loop count may be set from 1 to 999
times, with an entry of 0 indicating loop infinitely.
NOTE
The PC must be rebooted to cancel the infinite loop.
You are next asked whether the diagnostics should pause when an error is
detected.
If the response is “NO,” any errors detected by the diagnostics are displayed;
however, the diagnostics will immediately clear the screen and restart on the next
pass of the tests.
If you respond “YES,” any error detected is displayed and you must hit the
<ENTER> key to continue.