Black Box KVT16CATUV Computer Accessories User Manual


 
ServView KVM Module
724-746-5500 | blackbox.com
Page 10
3. Installation
3.1 Mounting
The KVM module is designed to interlock precisely with the rear of the ServView rack tray.
1 If the ServView rack tray is already fitted, either remove it or carefully gain access to the rear of the rack mount unit.
2 Locate the connection plate at the rear of the rack tray and orientate the KVM module so that its universal Centronics
®
36-pin
connector aligns with the socket on the connection plate. See Figure 3-1.
Figure 3-1. Aligning the KVM module with the connection plate of the rack tray.
3 Carefully slide the KVM module in so that its connector and two locating holes mate correctly with the corresponding connec-
tor and locating pins on the connection plate.
4 Tighten the locking screw until it is finger tight.
KVM module
Rack tray connection plate
(as viewed from the pull out
keyboard - side rails not
shown for clarity).
Universal Centronics
®
36-pin connector
Locating pins
Locking screw