Specify a label for the port.
Select the appropriate Baud Rate, Parity, Data Bits, Stop Bits, and Flow Control for each port.
(Note: The RS-485/RS-422 option is not relevant for console servers.)
Before proceeding with further serial port configuration, connect the ports to the serial devices
they will be controlling, and make sure they have matching settings.
Note The serial ports are all set at the factory to RS232 9600 baud, no parity, 8 data bits, 1 stop bit,
and Console server Mode. You can change the baud rate to 2400230400 baud using the
management console. You can configure lower baud rates (50, 75, 110, 134, 150, 200, 300, 600,
1200, 1800 baud) from the command line. Refer to Chapter 14— Basic Configuration (Linux
Commands).
4.1.2 Console Server Mode
Select Console Server Mode to enable remote management access to the serial console that is attached
to this serial port:
_____________________________________________________________________
724-746-5500 | blackbox.com Page 48