Blade ICE BMD00098 Switch User Manual


 
BLADE OS 5.1 Release Notes
16 BMD00098, December 2009
Chassis Internal Network
BLADEOS 5.1 now supports BladeCenter Chassis Internal Network (CIN). CIN provides internal
connectivity between blade server ports and the internal Advanced Management Module (AMM)
port. This allows blade server users to access the AMM via CLI, web-browser, or SNMP session,
and allows the AMM to use services on the blades, such as LDAP, SMTP, DNS, and NTP.
BC-S Chassis Support
BLADEOS 5.1 supports the BladeCenter BC-S chassis. When the GbESM is installed in the BC-S
chassis, the following information displays reflect the BC-S port mapping:
Port link information (
/info/link) for switches installed in bay 1 and bay 2:
Alias Port Speed Duplex Flow Ctrl Link
---- ----- ----- -------- --TX-----RX-- ------
INT1A 1 1000 full yes yes up
INT1B 2 1000 full yes yes up
INT2A 3 1000 full yes yes up
INT2B 4 1000 full yes yes up
INT3A 5 1000 full yes yes down
INT3B 6 1000 full yes yes up
INT4A 7 1000 full yes yes up
INT4B 8 1000 full yes yes up
INT5A 9 1000 full yes yes up
INT5B 10 1000 full yes yes up
INT6A 11 1000 full yes yes up
INT6B 12 1000 full yes yes up
SMGT1 13 1000 full yes yes up
SMGT2 14 1000 full yes yes up
MGT1 15 100 full yes yes up
EXT1 17 10000 any yes yes up
EXT2 18 10000 any yes yes up
EXT3 19 10000 any yes yes up
EXT4 20 1000 any yes yes up
EXT5 21 1000 any yes yes up
EXT6 22 1000 any yes yes up
EXT7 23 1000 any yes yes up
EXT8 24 1000 any yes yes up
EXT9 25 1000 any yes yes up