LTC 5104, LTC 5108 Series | Instruction Manual | Installation
4.11 Alarm Capture
This menu item appears only if the Auto Alarm reset
mode is selected (see SCREEN 5). When the Alarm
Capture is ON, alarm call ups are held for at least the
length of their Alarm Capture Time. After its Alarm
Capture Time has expired, the alarm call up remains as
long as its contact closure exists. When the Alarm
Capture is OFF, alarm call ups are held only as long as
its contact closure is detected. The default is ON.
Screen 5
4.12 Alarm Capture Time
This menu item appears only when the Alarm Capture
is ON (see SCREEN 6). The Capture Time specifies the
minimum length of time that the alarm call up will be
held, once its contact closure is detected. During
multiple alarms, the Capture Time expires only while
the alarm is being displayed. Use SKIP/clr to
decrease time and ALARM to increase time. Alarm
capture time can be set from 1 second to 63 seconds.
The default time is 14 seconds.
Screen 6
4.13 Alarm Dwell Time
The Alarm Dwell Time determines how long each alarm
call up is displayed during sequencing of multiple
alarms (see SCREEN 7). Use SKIP/clr to decrease
time and ALARM to increase time. Alarm Dwell Time
can be set from 1 second to 64 seconds. The default
time is two seconds.
Screen 7
4.14 Alarm Contact Closures
This screen enables the user to set alarm contact
closures as NORMALLY OPEN or NORMALLY
CLOSED. Press SKIP/clr to choose between the two
options. The default is NORMALLY OPEN (see
SCREEN 8).
Screen 8