BOXLIGHT cp-305t Projector User Manual


 
19
BASIC OPERATION
TURNING ON PROJECTOR
Connect the projector's AC Power Cord into an AC outlet. LAMP
Indicator lights RED, and READY Indicator lights GREEN.
Press POWER ON-OFF button on Top Control or on Remote
Control Unit to ON. LAMP Indicator dims, and Cooling Fans
start to operate. Preparation Display appears on a screen and
the count-down starts. The signal from PC or Video source
appears after 30 seconds.
2
3
TURNING OFF PROJECTOR
Press POWER ON-OFF button on Top Control or on Remote
Control Unit, and a message "Power off?" appears on a screen.
Press POWER ON-OFF button again to turn off projector. LAMP
Indicator lights bright and READY Indicator is turned off. After
projector is turned off, Cooling Fans operate (for 90 seconds).
During this "Cooling Down" period, this appliance cannot be
turned on.
1
2
TO MAINTAIN THE LIFE OF LAMP, ONCE YOU TURN
PROJECTOR ON, WAIT AT LEAST 5 MINUTES BEFORE
TURNING IT OFF.
TURNING ON / OFF PROJECTOR
When WARNING TEMP. Indicator flashes red, the projector is automatically turned off. Wait at least 5 minutes before
turning on projector again.
When WARNING TEMP. Indicator continues to flash, follow the procedures below:
1. Press POWER ON-OFF button to turn the projector off and disconnect AC Power Cord from an AC outlet.
2. Check Air Filters for dust accumulation.
3. Clean Air Filters. (See "AIR FILTER CARE AND CLEANING" section on page 38.)
4. Turn the projector on again.
If WARNING TEMP. Indicator should still continue to flash, call Boxlight at 1-800-762-5757 or 360-779-7901.
1
Complete peripheral connections (with Computer, VCR, etc.)
before turning on projector. (Refer to "CONNECTING TO
PROJECTOR" on pages 11~13 for connecting that equipment.)
3
When the projector has cooled down, READY Indicator lights
GREEN again and you can turn the projector on. After cooling
down completely, disconnect AC Power Cord.
30
Preparation Display disappears after 30 seconds.
Power off?
Message disappears after 4 seconds.
When Power Management function is ON, the projector detects signal interruption and turns off Projection Lamp
automatically. Refer to Power Management on page 36.
NOTE : When On start function is ON, this projector is turned
on automatically by connecting AC Power Cord to an
AC outlet. (Refer to pages 35, 36.)