Brother BE-1204B-BC All in One Printer User Manual


 
6-32 BE-1204B-BC • BE-1206B-BC
Chapter 6 Embroidering
Thread Breakage Sensor
The sensor for thread breakage can be turned ON/OFF or the sensor sensitivity for each needle
bar can be set.
! The sensitivity can be set within the range of 1 - 100. The smaller the value is, the higher the
sensitivity is.
1. Select [Thread Breakage Sensor] from Setting menu.
2. Click the head you want to disable the sensor and remove the check mark (
).
W1125Q
3. Adjust the sensor sensitivity.
W1126Q
4. Click [OK].
The sensor sensitivity for each
needle bar is adjusted individually.
A
ll sensor sensitivities for all needle
bars are adjusted simultaneously.
Set the lower thread breakage sensor
individually.