3. On the same side and with the help of a small jeweler screw-
driver release the three (3) clips holding the developer roller
bearing cap to the toner hopper. The first clip is right below the
screw holding the developer blade, the opposite clip is between
the side of the roll and the casing while the third one is accessi-
ble from outside the casing.
NOTES
1. With the use of small flat blade screwdriver, slightly pry up the
white plastic alignment hub located from the non-gear side of
the developer roller and remove it.
2. NOTE: Be aware of the pressure spring behind the white plas-
tic hub and do not lose it.