Be sure to complete the data transfer
before
making any
changes in the datalogger program. Changing a program and
then compiling it will advance the datalogger’s Storage Module
Pointer to the position of the DSP. If this is done before
connecting the Storage Module to allow the datalogger to
transfer the data, the old data will
not
be automatically
transferred to the Storage Module. Also, the Instruction 96
data transfer will not take place while the datalogger is in
communication with another device, e.g. a computer or an
active CR10KD.
2.1.1 Multiple Storage Modules with the CR500/510, CR10/10X or
CR23X
While eight Storage Modules can be addressed,
communication may be unreliable if more than four SM4M or
SM16M modules are connected to a datalogger. Contact
Campbell Scientific if you need to connect more than four
modules.