Casio CFX-9950GB PLUS Calculator User Manual


 
5
2-4 Digital Calipers
Description : Determines the distance between the
two terminals of the calipers and
produces it as a value on the display.
Probe : Voltage Probe
File Name : CALIPERS
2-5 Display
Description : Plots temperature values measured by the EA-100 every second for one minute.
Probe : Temperature Probe
File Name : DISPLAY
2-6 Range Finder
Description : Measures the distance to an object in
accordance with its distance and
direction (angle) from two reference
points.
Probe : Voltage Probe
File Name : DISTANCE
2-7 Electric Charge Curve of a
Capacitor
Description : Shows changes in capacitor terminal
voltage.
Probe : Voltage Probe
File Name : ELECHARG
Guide A
Guide B
Variable resistor
(Type A, 10k)
Red
(+5 to 10V)
Blue (+)
Black (G, )
To voltage probes
(Affix guide B to variable resistor tab B.)
x
O
θ
a
E
1
E
2
x
tan =
a
θ
x
=
––––
a
tan
θ
To EA-100
+ terminal
terminal
Resistor
Charge to 3 to 5V
40 F
µ
Variable resistor
(Type A, 10k)
Black (G, )
Blue (+)
To voltage probes
Red
(+5 to 10V)
A
B