Channel Plus 8052 Switch User Manual


 
Expansion connector
Jacks accept
6 position RJ-25
Or
8 position RJ-45
plugs
POTS (Plain Old Telephone Service)
Data/Telephone Hub applications
Tie wrap mounting holes
To phone jacks
110 punch-down blocks
Do not punch-down more
than one wire per
connector.
From Telco
Central Office lines (CO)
CO1, CO2, CO3, CO4
From Telco
Central Office lines (CO)
CO1, CO2, CO3, CO4
To distribute POTS, use either an 8051 or an 8053.
All connectors are ( ).bridged wired in parallel
Model
8051
Model
8053
Model 8053
Model 8052
Model 8051
Use a model 8053 to distribute telephone service. A single
model 8053 can handle up to 9 telephones. For more
phones, add one 8053 for every 8 telephones. All connectors
are bridged (wired in parallel.)
Use a model 8051 to distribute telephone service if you prefer
to use modular connectors. The model 8051 also provides
loopthrough on pair 1 for a security system or a DoorTel front
door intercom.
In a structured wiring system, a model 8051 is used to
provide selective telephone service. (See the section on
Structured Wiring Systems.)
All connectors are bridged (wired in parallel.)
In a structured wiring system, a model 8052 is used to
provide a termination point for all internal house wiring. (See
the section on Structured Wiring Systems.) Each modular
connector is individually connected to the 110 punch-down
block behind it.
Expansion connector
Jacks accept
6 position RJ-25
Or
8 position RJ-45
plugs
POTS (Plain Old Telephone Service)
Data/Telephone Hub applications
Tie wrap mounting holes
To phone jacks
110 punch-down blocks
Do not punch-down more
than one wire per
connector.
From Telco
Central Office lines (CO)
CO1, CO2, CO3, CO4
From Telco
Central Office lines (CO)
CO1, CO2, CO3, CO4
To distribute POTS, use either an 8051 or an 8053.
All connectors are ( ).bridged wired in parallel
Model
8051
Model
8053
Model 8053
Model 8052
Model 8051
Use a model 8053 to distribute telephone service. A single
model 8053 can handle up to 9 telephones. For more
phones, add one 8053 for every 8 telephones. All connectors
are bridged (wired in parallel.)
Use a model 8051 to distribute telephone service if you prefer
to use modular connectors. The model 8051 also provides
loopthrough on pair 1 for a security system or a DoorTel front
door intercom.
In a structured wiring system, a model 8051 is used to
provide selective telephone service. (See the section on
Structured Wiring Systems.)
All connectors are bridged (wired in parallel.)
In a structured wiring system, a model 8052 is used to
provide a termination point for all internal house wiring. (See
the section on Structured Wiring Systems.) Each modular
connector is individually connected to the 110 punch-down
block behind it.