System Management
• IronView Network Manager (INM)
• Web-based Graphical User Interface
• Embedded Web Management
• Industry Standard Command Line Interface (CLI)
• RMON HP OpenView for Sun Solaris
• HP-UX, IBM’s AIX, and Windows NT
• Virtual Cable Tester
• Repeater MIB
Element Security Options
• Authentication, Authorization, and Accounting (AAA)
• RADIUS
• Secure Shell (SSHv2)
• Secure Copy (SCP)
• TACACS/TACACS+
• Username/Password (Challenge and Response)
• Bi-level Access Mode (Standard and EXEC Level)
• Protection for Denial of Service attacks, such as TCP SYN or Smurf Attacks
Physical Design
• ETSI ETS 300 119-4, Engineering Requirements for Sub-racks in
misc. racks and cabinets
• ANSI/EIA-310-D, Cabinets, Racks, Panels, and Associated Equipment
Dimensions
FastIron SuperX and
FastIron SX 800
10.4” (H) x 17.5” (W) x 17.3” (D)
26.3 cm (H) x 44.5 cm (W) x 43.8 cm (D)
FastIron SX 1600 24.5” (H) x 17.5” (W) x 17.3” (D)
62.2 cm (H) x 44.5 cm (W) x 43.8 cm (D)
Weight (Fully Loaded)
FastIron SuperX and
FastIron SX 800
70 lbs (31 kg)
FastIron SX 1600 196 lbs (88.6 kg)
Environmental
• Operating temperature: 0ºC to 40ºC (32ºF to 104ºF)
• Relative humidity: 5 to 90%, @40ºC (104ºF, non condensing)
• Operating altitude: 6600 ft (2,000 m)
• Storage temperature: -25ºC to 70ºC (-13ºF to 158ºF)
• Storage humidity: 95% maximum relative humidity, non-condensing
• Storage altitude: 15,000 ft (4,500 m) maximum
MTBF
Chassis • SuperX Chassis, Fan Tray, 1 P/S: 269,386 hrs
• SX 800 Chassis, Fan Tray, 1 P/S: 142,786 hrs
• SX 800 Chassis, Fan Tray, 2 P/S: 230,584 hrs
• SX1600 Chassis, Fan Tray, 2 P/S: 99,908 hrs
• SX1600 Chassis, Fan Tray, 4 P/S: 213,865 hrs
Management Modules • IPv4 Management Module with no optics:
287,664 hrs
• IPv4 Management Module, Zero ports:
534,522 hrs
• IPv4 Management Module, 2x10-GbE ports:
269,436 hrs
• IPv6 Management Module, 256MB SDRAM,
no optics: 292,557 hrs
• IPv6 Management Module, 512MB SDRAM,
no optics: 287,425 hrs
• IPv6 Management Module, 2x10GbE,
no optics: 304,109 hrs
Interface modules (IPv4
and IPv6 versions)
• 24-port 10/100/1000 Copper Module:
352,103 hrs
• 24-port SFP Module: 348,204 hrs
• 2-port 10-GbE Module: 464,938 hrs
Power Requirements
System Power Supply
(SX-ACPWR, SX-DCPWR)
• -40 – -60 VDC Consumption (Amps): 36A
• 100 – 120 VAC Consumption (Amps): 14.3A
• 200 – 240 VAC Consumption (Amps): 7.2A
• AC Frequency: 50 – 60Hz
• Max BTU: 4874 BTU/Hr
• Max Watts (Output): 1200W
• Max Watts (Input): 1428W
1250W PoE Power Supply • 100 – 120 VAC Consumption (Amps): 14A
• 200 – 240 VAC Consumption (Amps): 7A
• AC Frequency: 50 – 60Hz
• Max BTU: 4736 BTU/Hr
• Max Watts (Output): 1250W
• Max Watts (Input): 1388W
2500W PoE Power Supply
(SX-ACPWR-2500-POE)
• 200 – 240 VAC Consumption (Amps): 14A
• AC Frequency: 50 – 60Hz
• Max BTU: 9471 BTU/Hr
• Max Watts (Output): 2500W
• Max Watts (Input): 2775W
Safety Certications
• CAN/CSA-C22.2 No. 60950-1-03
• Information Technology Equipment
• Safety—Part 1: General Requirement
• UL 60950-1, Information Technology Equipment—Safety—
Part 1: General Requirement
• EN 60950-1, Information Technology Equipment—Safety—
Part 1: General Requirement
• IEC 60950-1, Information Technology Equipment—Safety—
Part 1: General Requirement
• EN 60825-1, Safety of Laser Products. Equipment Classication,
Requirements and User Guide
• EN 60825-2, Safety of Laser Products, Safety of Optical Fibre
Communications Systems
Environmental Regulatory Compliance
• RoHS Compliant (5 of 6)
• WEEE compliant
Electromagnetic Emission Certications
• ICES-003, Electromagnetic Emission
• FCC Class A
• EN 55022/CISPR 22 Class A
• VCCI Class A
• EN 61000-3-2, Power Line Harmonics
• EN 61000-3-3, Voltage Fluctuation and Flicker
• EN 61000-6-3, Electromagnetic Compatibility
• AS/NZS CISPR 22, Electromagnetic Compatibility
Immunity
EN 61000-6-1, Electromagnetic Compatibility, Generic Standard
EN 55024, Immunity Characteristics Supersedes:
• EN 61000-4-2, ESD
• EN 61000-4-3, Radiated, Radio Frequency, Electromagnetic Field
• EN 61000-4-4, Electrical Fast Transient
• EN 61000-4-5, Surge
• EN 61000-4-6, Conducted Disturbances Induced by Radio
• Frequency Fields
• EN 61000-4-8, Power Frequency Magnetic Field
• EN 61000-4-11, Power Frequency Magnetic Field
Mounting Options
• 19” Universal EIA (Telco) Rack or Tabletop