Cisco Systems UCS C220 M3 Server User Manual


 
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
25
Approved Configurations
(1) No RAID controller plug-in card
If you did not choose a plug-in RAID controller (for example, you are using embedded RAID
or a mezzanine RAID controller), you can select up to two PCie option cards listed in
Tab le 9.
(2) One RAID controller plug-in card
If you selected a plug-in PCIe RAID controller, you can select only one of the optional PCIe
cards listed in
Table 9.
Caveats
For 1-CPU systems:
Only the full-height PCIe slot (slot 1) is supported
Neither PCIe slot 2 nor the mezzanine card slot are supported
Only a single VIC card (either the full-height Cisco UCS P81E or the Cisco VIC 1225
PCIe card) is supported and it must be installed in slot 1 (the full-height slot).
For 2-CPU systems:
Both PCIe slots and the mezzanine card slot are supported
Only a single VIC card (either the full-height Cisco UCS P81E or the half-height Cisco
VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full height
slot).
All PCIe cards will fit in either slot, except the Cisco UCS P81E Virtual Interface Card (VIC),
which must be installed in the full-height slot (slot 1).
Other considerations for the Cisco VIC 1225:
Supports 10G SFP+ optical and copper twinax connections
Requires that the server has CIMC firmware version 1.4(6) or later installed. There is
a heartbeat LED on the top of the card that indicates when firmware is active.
To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS
Manager 2.1(0) or later, the minimum card-firmware and uboot image level is
2.1(0.306).
To help ensure that your operating system is compatible with the card you have selected,
check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
NOTE: If a plug-in RAID controller card is installed, any optional PCIe card you select
will be installed in the full-height slot. RAID controllers are always installed in the
half-height slot.