5.2 Manual Setting of Memory Switch
Memory switches can be set manually or by a command.
For manual setting, refer to the next page.
The function of each memory switch is shown in the following table. (The
white-on-black characters are factory setting.)
Switch No. Setting 0 (OFF) 1 (ON)
Memory SW1-1 Power ON Info Send Not send
Memory SW1-2 Buffer Size 4k bytes 45 bytes
Memory SW1-3 Busy Condition Full/Err Full
Memory SW1-4 Receive Error Print “?” No Print
Memory SW1-5 CR mode Ignored LF
Memory SW1-6 Reserved Fixed
Memory SW1-7 DSR Signal Invalid Valid
Memory SW1-8 Init Signal Invalid Valid
Memory SW2-1 Reserved Fixed
Memory SW2-2 Auto Cutter Invalid Valid
Memory SW2-3 Spool Print Invalid Valid
Memory SW2-4 Full Col Print CBM1000 EPSON
Memory SW2-5 Resume aft PE Next Top
Memory SW2-6 Paper width 80 mm 58 mm
Memory SW2-7 Reserved Fixed
Memory SW2-8 NPE Sensor Valid Invalid
Memory SW3-1 Resum Cttr Err Feed S/W Command
Memory SW3-2 Resum Open Err Close Command
Memory SW3-3 Parallel 31 Pin Valid Invalid
Memory SW3-4 Paper Select Thermal Black MK
Memory SW3-5 Column Number 48/32 col 42/30 col
Memory SW3-6 No use Fixed
Memory SW3-7
CBM1000 Mode
Invalid Valid
Memory SW3-8
Open w/Printing
Auto Manual
Memory SW4-1 Auto Length Invalid Valid
Memory SW4-2 BM Sensor Surface Back
Memory SW4-3 No use OFF Fixed
Memory SW4-4 No use OFF Fixed
Memory SW4-5 No use OFF Fixed
Memory SW4-6 No use OFF Fixed
Memory SW4-7 No use OFF Fixed
Memory SW4-8 Full Cut Cmd Full Cut Partial