Citizen Systems CT-S310 Printer User Manual


 
— 25 —
5. OTHER
5.1 External Views and Dimensions
(Unit: millimeter)
Built-in Power Supply Type
AC Adapter Type
195
121
84
145
159
86
145
195
5.2 Manual Setting of Memory Switch
Memory switches can be set manually or by a command.
For manual setting, refer to the next page.
The function of each memory switch is shown in the following table.
(The white-on-black characters are factory setting.)
Switch No. Setting 0 (OFF) 1 (ON)
Memory SW1-1 Power ON Info Valid Not send
SW1-2 Buffer Size 4K bytes 45 bytes
SW1-3 Busy Condition Full/Err Full
SW1-4 Receive Error Print ? No Print
SW1-5 CR mode Ignored LF
SW1-6 Reserved Fixed
SW1-7 DSR Signal Invalid Valid
SW1-8 Init Signal Invalid Valid
Memory SW2-1 Reserved Fixed
SW2-2 Auto Cutter Invalid Valid
SW2-3 Spool Print Invalid Valid
SW2-4 Full Col Print LineFeed WaitData
SW2-5 Resume aft PE Next Top
SW2-6 Paper width 80mm 58mm
SW2-7 Reserved Fixed
SW2-8 PNE Sensor Valid Invalid