ClearOne comm AP10 Network Card User Manual


 
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
The AP10 has four basic functions: make a call, answer a call, disconnect a call, and
mute. This chapter explains how to perform these functions with the AP10 unit and
a telephone handset (optional) and with the Telco interface in AP-Ware. You can also
use touch panels and custom control devices.
To answer a call
Depending on how you have configured your AP10, an incoming call can ring on the
telephone set connected to the AP10, the receive output, and pass a serial ring to the
control device. An incoming call will also cause the front panel On LED to flash. You
can answer the call in one of two ways:
Press the On button [D] on either the front panel or from your remote
control. This will route the call through the AP10 to the AP800. The green
On LED will light. The red Off LED will extinguish.
– or –
Answer the call by picking up the telephone handset and talking to your
party over the telephone.
To make and disconnect a call
1. Call the party using your handset.
2. After the other party has answered, route the call through the AP10 by
pressing the On button [D]. The On LED will light and the AP10 will take
control of the call, disabling the telephone set. You can now safely hang up
the handset without disconnecting your call.
If using an external controller, it is not necessary to press the On button
[D]. The DIAL serial command automatically engages the AP10. See Serial
Commands, page 22.
CHAPTER 4: Operation
Using the AP10
A
B
CD
E
Figure 4.1. AP10 front panel controls
If auto-answer is enabled
(DIP switch 4), the AP10
will answer after the first
complete ring.
If auto-disconnect is
enabled (DIP switch 5),
the AP10 will disconnect
upon sensing loop drop or call-
progress tones (depending on the
position of DIP switch 6).