Installation Requirements
•
The inverter must be installed in an area that meets
all of the following requirements:
A. Dry
Do not place in an area where water can drip
or splash on the inverter.
B. Cool
Ambient air temperature should be between 30°F
and 105°F (0°C and 40°C). The cooler the better.
C. Ventilate
Allow at least 1 inch (3 cm) of clearance around the
inverter for proper airflow. Make sure that ventilation
openings on the ends of the unit are not obstructed.
CAUTION To avoid fire, do not cover or obstruct
ventilation openings. Do not install inverter in a zero-
clearance compartment. Overheating may result.
CAUTION The inverter must only be connected
to batteries with a nominal output voltage of 12
volts. It will not work with a 6 volt battery, and will
be damaged if it is connected to a 16 volt battery.
WARNING This unit contains components
which can produce arcs or sparks. To prevent
fire or explosion, do not install in compartments
containing a battery or flammable materials,
or in a location which requires ignition
protected equipment.
Mounting
•
To Mount Your Inverter:
1. Place the inverter on a flat surface with the mounting
bracket against the mounting surface.
2. Mount to secure surface using mounting hardware
that is corrosion resistant (not included).
The inverter can be mounted horizontally or vertically.
Installation
Installation
Requirements
Installation
Mounting Brackets
Mounting Hardware