Compaq dc5750 Laptop User Manual


 
Unit Environment and Operating
Conditions
Microtower
Small Form Factor
General Unit Operating Guidelines (Need this updated for dc5750)
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that
unit is operated within the specified operating range.
Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each
other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other
foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Operating: 50° to 95° F (10° to 35° C)*
Non-operating: -22° to 140° F(-30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude
(unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*
NOTE:
Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct
sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of
options installed.
Microtower
Small Form Factor
Power Supply
300-watt BTX power
supply – Passive
PFC
115v/230v line switch
300-watt 80Plus*
BTX power supply –
Active PFC
240-watt BTX power
supply – Passive
PFC
115v/230v line switch
240-watt 80Plus*
BTX power supply –
Active PFC
Operating Voltage Range
90 to 132VAC, or 180
to 264VAC
90 to 264VAC
90 to 132VAC, or 180
to 264VAC
90 to 264VAC
Rated Voltage Range
100 to 127VAC, or
200 to 240VAC
100 to 240VAC
100 to 127VAC, or
200 to 240VAC
100 to 240VAC
Rated Line Frequency
50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Operating Line Frequency Range
47–63 Hz 47–63 Hz 47–63 Hz 47–63 Hz
Rated Input Current
8A/4A
5A/2.5A
6A/3A
3.5A/1.75
Heat Dissipation
Typical 315 btu/hr
(79 kg-cal/hr)
Maximum 1575 btu/hr
(397 kg-cal/hr)
Typical 270 btu/hr
(68 kg-cal/hr)
Maximum 1280 btu/hr
(322 kg-cal/hr)
Typical 315 btu/hr
(79 kg-cal/hr)
Maximum
1260 btu/hr
(317 kg-cal/hr)
Typical 270 btu/hr
(68 kg-cal/hr)
Maximum 1025 btu/hr
(258 kg-cal/hr)
Power Supply Fan
Variable speed fan Variable speed fan Variable speed fan Variable speed fan
Energy Star 3.0 Compliant
X X X X
Energy Star 4.0 Compliant
X X
FEMP Standby Power Compliant
(<2W in S5 – Power Off)**
X X X X
Power Consumption in ES Mode
– Suspend to RAM (S3)
(Instantly Available PC)
<4W <3W <4W <3W
QuickSpecs
HP Compaq dc5750 Business PC
Technical Specifications
DA - 12546 Worldwide QuickSpecs — Version 10 — 1.30.2007
Page 15