Compaq DS-DWZZH-05 Switch User Manual


 
Table 2–2: Hardware Components Used in the Configuration Shown in
Figure 2–3
Callout Number Description
1
BN38C HD68 to VHDCI cable
ab
2 H885-AA HD68 trilink connector
3 H879-AA HD68 terminator
4 BN21K or BN21L HD68 cable
b
a
The maximum length of the SCSI bus segment, including BN38C cable and internal device length, must
not exceed 25 meters.
b
The maximum length of the SCSI bus segment, including the combined length of the BN38C and BN21K
(or BN21L) cables, must not exceed 25 meters.
2.7.3.2 Cabling an HSZ70 to a DS-DWZZH-05 UltraSCSI Hub
To prepare the storage portion of a cluster using HSZ70 RAID array
controllers, follow these steps while referring to Figure 2–4 and Table 2–3:
1. Install an H8861-AA trilink connector on each HSZ70 controller port
on the SCSI bus segment.
2. Attach an H8863-AA terminator to the H8861-AA connector on the
HSZ70 controller that will be on the end of the SCSI bus segment.
3. If there are two HSZ70 controllers, connect the two H8861-AA trilink
connectors on the controllers with a BN37A cable.
4. Connect the DS-DWZZH-05 to the HSZ70 H8861-AA trilink with a
BN37A cable.
_____________________ Note _____________________
The maximum length of a SCSI bus segment, including
cable and internal device SCSI bus length must not exceed
25 meters.
Figure 2–4 shows a sample configuration that uses a KZPBA-CB SCSI
adapter, a DS-DWZZH-05 UltraSCSI hub, and an HSZ70 RAID array
controller.
2–10 Using the DS-DWZZH-05 UltraSCSI Hub in a Cluster Configuration