12 T
ROUBLESHOOTING
P
RESARIO
N
OTEBOOK
M
AINTENANCE
AND
S
ERVICE
G
UIDE
1200XL S
ERIES
Presario 1200 Series
Models: XL101-XL113, XL115, XL118-XL127
Diskette Drive Test Error Codes
Error Code Description Recommended Action
600-xx Diskette ID drive types test
failed
1. Replace the diskette media and
retest.
2. Check and/or replace the diskette
power and signal cables and retest.
3. Replace the diskette and retest.
4. Replace the system board and retest.
601-xx Diskette format failed
602-xx Diskette read test failed
603-xx Diskette write, read, compare
test failed
604-xx Diskette random read test failed
605-xx Diskette ID media failed
606-xx Diskette speed test failed
609-xx Diskette reset controller test
failed
610-xx Diskette change line test
697-xx Diskette type error
698-xx Diskette drive speed not within
limits
699-xx Diskette drive/media ID error
1. Replace media.
2. Run the Configuration and Diagnostics
Utilities.
Serial Test Error Codes
Error Code Description Recommended Action
1101-xx Serial port test failed
1. Check port configuration.
2. Replace the system board and retest.