Connect Tech CTIM-00015 Computer Hardware User Manual


 
BlueStorm Installation Guide, Connect Tech Inc.
Revision 0.08 13
Note that Auto 485 is a single jumper. The second site is not in use. See
Figure 1 for the location of this jumper.
Power-On Tri-state (BlueStorm/SP models only, excludes
BlueStorm/SP RJ-11)
BlueStorm/SP models offer a power-on tri-state similar to the Auto-485 mode listed above. The
BlueStorm/SP implementation will tri-state ports configured as RS-485 full duplex. This is
meant to ensure compatibility with our legacy Blue Heat/PCI cards.
Jumper J1 controls the power-on tri-state functionality. Install a jumper on the first location of
the J1 in order to tri-state Port 1 at power-on, install a jumper on the second position for Port 2,
etc. Ports will not come out of tri-state until the driver opens the affected port.
Half Duplex and Multi-drop Slave modes require you to select the appropriate
mode via software. Please refer to the readme.txt files found in the appropriate
directories on the BlueStorm/LP/SP/SP Opto CD.
Connectors and Pinouts
Table 1: DB-25 Female Pinouts for BlueStorm/LP (2 port connector)
Pin
No.
Port
No.
RS-232
Signal
Signal
Direction
RS-422/485
Signal
Signal
Direction
1 2 SG signal gnd. SR signal ref.
2 1 TXD output TXD- output
3 1 RXD input TXD+ output
4 1 RTS output RTS- output
5 1 CTS input RTS+ output
6 1 DSR input CTS- input
7 1 SG signal gnd. SR signal ref.
8 1 DCD input RXD+ input
9 2 TXD output TXD- output
10 2 RXD input TXD+ output
11 2 RTS output RTS- output
12 2 CTS input RTS+ output
13 2 DSR input CTS- input
14 NC no connect NC no connect
15 NC no connect NC no connect
16 NC no connect NC no connect
17 NC no connect NC no connect
18 NC no connect NC no connect
19 2 DTR output RXD- input
20 1 DTR output RXD- input
21 NC no connect NC no connect
22 1 RI input CTS+ input
23 2 RI input CTS+ input
24 NC no connect NC no connect
25 2 DCD input RXD+ input
Cable CBG002 sends the signals to two DB-9 male connectors. See Table 6 for pinout details.
NOTE: This is not the pinout of DB-25 cable CBG007.