CyberPower Systems CPS1500AVR Power Supply User Manual


 
TROUBLESHOOTING
14
General Model CPS1500AVR
Capacity 1500AV (950W)
Input Frequency 47Hz - 63Hz
Voltage Range 85v - 150v
UPS- Output Line Conditioning Regulation AVR Max. boost 15% of input voltage for output regulation
while input voltage is from 8% to 30% under nominal
AVR Max. buck 15% of input voltage for output regulation
while input voltage is from 8% to 26% over nominal
On Battery Output Voltage 120 Vac ÿ± 5% (user adjustable)
Transfer Time 4ms typical, including detection time
On Battery Output Wave Form Simulated Sine Wave Form
Max. Load 1500VA (950W)
Battery Battery Type Sealed, maintenance-free lead acid battery
Number of Batteries 12v/7AH x 4
Recharge Time 4 to 8 hours from total discharge
Interface Communication RS-232 with Plug and Play interface
LED Indicators Power On, Electrical Wiring Fault, AVR, Using Battery,
Battery Charge Level, Load Level
Ouput Receptacles 6 Battery-powered and full-time surge protection
SPECIFICATIONS
tech@cyberpowersystems.com
tech@cyberpowersystems.com
tech@cyberpowersystems.com
tech@cyberpowersystems.com
Problem Possible Cause Solution
Outlets do not provide Circuit breaker is tripped due Turn the UPS off and unplug at least one
power to equipment to overload piece of equipment. Wait 10 seconds, reset
the circuit breaker and then turn the UPS on.
Batteries are discharged Allow the unit to recharge for at least 4 hours.
Unit has been damaged by a Contact CyberPower Systems at
surge or spike.
The UPS does not Batteries are not fully charged. Recharge the battery by leaving the UPS
perform expected runtime. plugged in.
Batteries are worn out. Contact CyberPower Systems at
The UPS will not turn on. The on/off switch is designed to Turn the UPS off. Wait 10 seconds and then
prevent damage by rapidly turn the UPS on.
turning it off and on.
The unit is not connected to an The unit must be connected to a 110/120v outlet.
AC outlet.
The batteries are worn out. Contact CyberPower Systems at
Mechanical problem. Contact CyberPower Systems at
PowerPanel Plus™ is The serial cable is not connected. Connect the serial cable to the UPS unit and an
inactive (all icons are gray). open serial port on the back of the computer.
You must use the cable that came with the unit.
The serial cable is connected to The primary computer must be connected to
the wrong port. Port I on the UPS. Check the back of the
computer for a different serial port. Move the
cable to this port.
The unit is not providing battery Turn the UPS off. Wait 10 seconds and then
power. turn the UPS on. This should reset the unit.
The serial cable is not the cable You must use the cable that came with the unit.
that was provided with the unit.