Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature .................................65°C to +150°C
Ambient Temperature with
Power Applied.............................................55°C to +125°C
Supply Voltage to Ground Potential............... 0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State
[3]
............................................ 0.5V to +7.0V
DC Input Voltage
[3]
......................................... 0.5V to +7.0V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage........................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current.................................................... >200 mA
Operating Range
Range
Ambient
Temperature V
CC
Commercial 0°C to +70°C 5V ± 10%
Industrial 40°C to +85°C 5V ± 10%
Electrical Characteristics Over the Operating Range
7C185-15 7C185-20
Parameter Description Test Conditions Min. Max. Min. Max. Unit
V
OH
Output HIGH Voltage V
CC
= Min., I
OH
= 4.0 mA 2.4 2.4 V
V
OL
Output LOW Voltage V
CC
= Min., I
OL
= 8.0 mA 0.4 0.4 V
V
IH
Input HIGH Voltage 2.2 V
CC
+
0.3V
2.2 V
CC
+
0.3V
V
V
IL
Input LOW Voltage
[3]
0.5 0.8 0.5 0.8 V
I
IX
Input Load Current GND V
I
V
CC
5 +5 5 +5 µA
I
OZ
Output Leakage
Current
GND V
I
V
CC
,
Output Disabled
5 +5 5 +5 µA
I
OS
Output Short
Circuit Current
[4]
V
CC
= Max.,
V
OUT
= GND
300 300 mA
I
CC
V
CC
Operating
Supply Current
V
CC
= Max.,
I
OUT
= 0 mA
130 110 mA
I
SB1
Automatic
Power-Down Current
Max. V
CC
, CE
1
V
IH
or CE
2
V
IL
Min. Duty Cycle = 100%
40 20
mA
I
SB2
Automatic
Power-Down Current
Max. V
CC
, CE
1
V
CC
0.3V,
or CE
2
0.3V
V
IN
V
CC
0.3V or V
IN
0.3V
15 15
mA
Notes:
3. Minimum voltage is equal to 3.0V for pulse durations less than 30 ns.
4. Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.