3.3V TAP AC Test Conditions
Input pulse levels ................................................ V
SS
to 3.3V
Input rise and fall times................................................... 1 ns
Input timing reference levels...........................................1.5V
Output reference levels...................................................1.5V
Test load termination supply voltage...............................1.5V
3.3V TAP AC Output Load Equivalent
2.5V TAP AC Test Conditions
Input pulse levels.................................................V
SS
to 2.5V
Input rise and fall time .....................................................1 ns
Input timing reference levels......................................... 1.25V
Output reference levels ................................................ 1.25V
Test load termination supply voltage ............................ 1.25V
2.5V TAP AC Output Load Equivalent
TAP AC Switching Characteristics
Over the Operating Range
[10, 11]
Parameter Description Min. Max. Unit
Clock
t
TCYC
TCK Clock Cycle Time 50 ns
t
TF
TCK Clock Frequency 20 MHz
t
TH
TCK Clock HIGH time 20 ns
t
TL
TCK Clock LOW time 20 ns
Output Times
t
TDOV
TCK Clock LOW to TDO Valid 10 ns
t
TDOX
TCK Clock LOW to TDO Invalid 0 ns
Set-up Times
t
TMSS
TMS Set-up to TCK Clock Rise 5 ns
t
TDIS
TDI Set-up to TCK Clock Rise 5 ns
t
CS
Capture Set-up to TCK Rise 5 ns
Hold Times
t
TMSH
TMS Hold after TCK Clock Rise 5 ns
t
TDIH
TDI Hold after Clock Rise 5 ns
t
CH
Capture Hold after Clock Rise 5 ns
T
DO
1.5V
20p
F
Z = 50
O
50
T
DO
1.25V
20p
F
Z = 50
O
50
TAP DC Electrical Characteristics And Operating Conditions
(0°C < T
A
< +70°C; V
DD
= 3.3V ±0.165V unless otherwise noted)
[12]
Parameter Description Conditions Min. Max. Unit
V
OH1
Output HIGH Voltage I
OH
= –4.0 mA V
DDQ
= 3.3V 2.4 V
I
OH
= –1.0 mA V
DDQ
= 2.5V 2.0 V
V
OH2
Output HIGH Voltage I
OH
= –100 µA V
DDQ
= 3.3V 2.9 V
V
DDQ
= 2.5V 2.1 V
V
OL1
Output LOW Voltage I
OL
= 8.0 mA V
DDQ
= 3.3V 0.4 V
I
OL
= 8.0 mA V
DDQ
= 2.5V 0.4 V
Notes:
10. t
CS
and t
CH
refer to the set-up and hold time requirements of latching data from the boundary scan register.
11. Test conditions are specified using the load in TAP AC test Conditions. t
R
/t
F
= 1 ns.
12.All voltages referenced to V
SS
(GND).