Cypress CY7C1513JV18 Computer Hardware User Manual


 
CY7C1511JV18, CY7C1526JV18
CY7C1513JV18, CY7C1515JV18
Document Number: 001-12560 Rev. *C Page 23 of 27
Switching Characteristics
Over the Operating Range
[21]
Cypress
Parameter
Consortium
Parameter
Description
300 MHz
Unit
Min Max
t
POWER
V
DD
(Typical) to the First Access
[22]
1ms
t
CYC
t
KHKH
K Clock and C Clock Cycle Time 3.3 8.4 ns
t
KH
t
KHKL
Input Clock (K/K; C/C) HIGH
1.32 ns
t
KL
t
KLKH
Input Clock (K/K; C/C) LOW
1.32 ns
t
KHKH
t
KHKH
K Clock Rise to K Clock Rise and C to C Rise (rising edge to rising edge)
1.49 ns
t
KHCH
t
KHCH
K/K Clock Rise to C/C Clock Rise (rising edge to rising edge)
01.45ns
Setup Times
t
SA
t
AVKH
Address Setup to K Clock Rise 0.4 ns
t
SC
t
IVKH
Control Setup to Clock (K, K) Rise (RPS, WPS)
0.4 ns
t
SCDDR
t
IVKH
Double Data Rate Control Setup to Clock (K, K) Rise (BWS
0
, BWS
1
,
BWS
2
, BWS
3
)0.3– ns
t
SD
t
DVKH
D
[X:0]
Setup to Clock (K/K) Rise
0.3 ns
Hold Times
t
HA
t
KHAX
Address Hold after Clock (K/K) Rise
0.4 ns
t
HC
t
KHIX
Control Hold after Clock (K /K) Rise (RPS, WPS)0.4ns
t
HCDDR
t
KHIX
Double Data Rate Control Hold after Clock (K/K) Rise (BWS
0
, BWS
1
, BWS
2
, BWS
3
)0.3 – ns
t
HD
t
KHDX
D
[X:0]
Hold after Clock (K/K) Rise
0.3 ns
Output Times
t
CO
t
CHQV
C/C Clock Rise (or K/K in single clock mode) to Data Valid
–0.45ns
t
DOH
t
CHQX
Data Output Hold after Output C/C Clock Rise (Active to Active)
–0.45 ns
t
CCQO
t
CHCQV
C/C Clock Rise to Echo Clock Valid
–0.45ns
t
CQOH
t
CHCQX
Echo Clock Hold after C/C Clock Rise
–0.45 ns
t
CQD
t
CQHQV
Echo Clock High to Data Valid 0.27 ns
t
CQDOH
t
CQHQX
Echo Clock High to Data Invalid –0.27 ns
t
CQH
t
CQHCQL
Output Clock (CQ/CQ) HIGH
[23]
1.24 ns
t
CQHCQH
t
CQHCQH
CQ Clock Rise to CQ Clock Rise
(rising edge to rising edge)
[23]
1.24 ns
t
CHZ
t
CHQZ
Clock (C and C) Rise to High-Z (Active to High-Z)
[24, 25]
–0.45ns
t
CLZ
t
CHQX1
Clock (C and C) Rise to Low-Z
[24, 25]
–0.45 ns
DLL Timing
t
KC Var
t
KC Var
Clock Phase Jitter 0.20 ns
t
KC lock
t
KC lock
DLL Lock Time (K, C) 1024 Cycles
t
KC Reset
t
KC Reset
K Static to DLL Reset 30 ns
Notes
22.This part has a voltage regulator internally; t
POWER
is the time that the power must be supplied above V
DD
minimum initially before a read or write operation can be
initiated.
23.These parameters are extrapolated from the input timing parameters (t
KHKH
- 250 ps, where 250 ps is the internal jitter. An input jitter of 200 ps (t
KC Var
) ia already
included in the t
KHKH
). These parameters are only guaranteed by design and are not tested in production
24.t
CHZ
, t
CLZ
, are specified with a load capacitance of 5 pF as in (b) of AC Test Loads and Waveforms on page 22. Transition is measured ± 100 mV from steady-state voltage.
25.At any voltage and temperature t
CHZ
is less than t
CLZ
and t
CHZ
less than t
CO
.
[+] Feedback