CY7C1511JV18, CY7C1526JV18
CY7C1513JV18, CY7C1515JV18
Document Number: 001-12560 Rev. *C Page 21 of 27
Maximum Ratings
Exceeding maximum ratings may impair the useful life of the
device. These user guidelines are not tested.
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with Power Applied.... –10°C to +85°C
Supply Voltage on V
DD
Relative to GND........–0.5V to +2.9V
Supply Voltage on V
DDQ
Relative to GND.......–0.5V to +V
DD
DC Applied to Outputs in High-Z ........ –0.5V to V
DDQ
+ 0.3V
DC Input Voltage
[13]
.............................. –0.5V to V
DD
+ 0.3V
Current into Outputs (LOW) ........................................ 20 mA
Static Discharge Voltage (MIL-STD-883, M. 3015).. > 2001V
Latch-up Current ................................................... > 200 mA
Operating Range
Range
Ambient
Temperature (T
A
) V
DD
[17]
V
DDQ
[17]
Commercial 0°C to +70°C 1.8 ± 0.1V 1.4V to
V
DD
Industrial –40°C to +85°C
Electrical Characteristics
DC Electrical Characteristics
Over the Operating Range
[14]
Parameter Description Test Conditions Min Typ Max Unit
V
DD
Power Supply Voltage 1.7 1.8 1.9 V
V
DDQ
IO Supply Voltage 1.4 1.5 V
DD
V
V
OH
Output HIGH Voltage Note 18 V
DDQ
/2 – 0.12 V
DDQ
/2 + 0.12 V
V
OL
Output LOW Voltage Note 19 V
DDQ
/2 – 0.12 V
DDQ
/2 + 0.12 V
V
OH(LOW)
Output HIGH Voltage I
OH
= −0.1 mA, Nominal Impedance V
DDQ
– 0.2 V
DDQ
V
V
OL(LOW)
Output LOW Voltage I
OL
= 0.1 mA, Nominal Impedance V
SS
0.2 V
V
IH
Input HIGH Voltage V
REF
+ 0.1 V
DDQ
+ 0.3 V
V
IL
Input LOW Voltage –0.3 V
REF
– 0.1 V
I
X
Input Leakage Current GND ≤ V
I
≤ V
DDQ
−5 5 μA
I
OZ
Output Leakage Current GND ≤ V
I
≤ V
DDQ,
Output Disabled −5 5 μA
V
REF
Input Reference Voltage
[20]
Typical Value = 0.75V 0.68 0.75 0.95 V
I
DD
V
DD
Operating Supply V
DD
= Max,
I
OUT
= 0 mA,
f = f
MAX
= 1/t
CYC
(x8) 1090 mA
(x9) 1090
(x18) 1115
(x36) 1140
I
SB1
Automatic Power down
Current
Max V
DD
,
Both Ports Deselected,
V
IN
≥ V
IH
or V
IN
≤ V
IL
f = f
MAX
= 1/t
CYC
,
Inputs Static
(x8) 405 mA
(x9) 405
(x18) 405
(x36) 405
AC Electrical Characteristics
Over the Operating Range
[13]
Parameter Description Test Conditions Min Typ Max Unit
V
IH
Input HIGH Voltage V
REF
+ 0.2 – – V
V
IL
Input LOW Voltage – – V
REF
– 0.2 V
Notes
17.Power up: Assumes a linear ramp from 0V to V
DD
(min) within 200 ms. During this time V
IH
< V
DD
and V
DDQ
< V
DD
.
18.Output are impedance controlled. I
OH
= −(V
DDQ
/2)/(RQ/5) for values of 175 ohms <= RQ <= 350 ohms.
19.Output are impedance controlled. I
OL
= (V
DDQ
/2)/(RQ/5) for values of 175 ohms <= RQ <= 350 ohms.
20.V
REF
(min) = 0.68V or 0.46V
DDQ
, whichever is larger, V
REF
(max) = 0.95V or 0.54V
DDQ
, whichever is smaller.
[+] Feedback